Description of Issue
|
R12.2 ADOP: AutoPatch error: The worker should not have status 'Running' or 'Restarted' at this point. AutoPatch error: Error running SQL and EXEC commands in parallel |
Cause
|
ADOP Patch Session got terminated abnormally due to network issue or patch hung or Lost connectivity. Error encountered when tried to re-start adop patch. |
Solution
|
1. Start Adctrl and look at the worker status. Are workers running or started? Select option: 1. Show Worker Status then 4. Tell manager that a worker failed its job 2. Restart the adop patch from the begining. Use below options: - If you want to restart a failed patch from the very beginning, you need to specify below options with adop restart=no abandon=yes - If you want to restart a failed patch from where it left off, you only need to specify below options with adop restart=yes abandon=no |